Calculate the extension factor and added stops caused by close focusing, then compare shutter-time or aperture compensation with a digital ISO-only brightness adjustment.
Lens, extension, and metered settings
Focal length and extension must use the same unit.
Use actual focal length, not a crop-equivalent value.
Enter total optical extension after focusing, measured from the film/sensor plane to the rear nodal point, not additional draw beyond infinity. Under the simple-lens assumption, a 150 mm lens with 75 mm of additional draw requires 225 mm total extension.
Seconds or a fraction: 1/125, 0.5, or 2.
Enter the f-number only, such as 8 or 16.
Used only to show the ISO-only compensation option.
🔒Privacy behavior has not been verified: whether inputs are tracked or uploaded, and whether processing occurs entirely on your device, is unconfirmed.
Exposure compensation
Bellows exposure factor2.25×
Add 1.17 stops of exposure
Aperture-only settingf/10.7Instead of changing shutter or ISO
ISO-only settingISO 225Instead of changing shutter or aperture
Choose one compensation method, not all three. Lengthening shutter time preserves the selected aperture and depth-of-field intent.
Bellows extension reference
The table uses the focal length and optional metered settings above. The highlighted row is the current extension ratio.
Extension ratio
Total extension
Exposure factor
Added stops
Corrected shutter
Effective aperture
Enter valid values to build the reference table.
How to calculate bellows exposure compensation
Compose and focus first. Bellows draw changes with focus, so measure the camera in its final focused position.
Enter the actual focal length. A 150 mm lens remains 150 mm regardless of film or sensor format.
Measure total optical extension. Measure from the film or sensor plane to the rear nodal point. For many conventional large-format lenses, the diaphragm or lens-board plane is a practical field approximation.
Enter the meter reading. Shutter, aperture, and ISO are optional; the factor and stops require only the two lengths.
Apply one compensation. Multiply shutter time by the factor or open aperture by the displayed stop amount to increase light exposure. With digital capture, multiplying ISO by the factor is an alternative brightness adjustment at unchanged shutter and aperture; it does not increase the light captured. Changing a meter’s ISO setting does not change the sensitivity of loaded film, so the ISO-only output is not a film exposure compensation method. Do not apply these alternatives cumulatively.
Check the capture. Bracket film or inspect a digital test frame when the subject is critical or the lens design makes physical measurement uncertain.
Bellows factor formulas
Let E be total optical extension, f lens focal length, F exposure factor, and C the added compensation in stops. Both lengths must use the same unit.
F = (E / f)²
C = log₂(F) = 2 × log₂(E / f)
corrected shutter time = metered time × F
A 150 mm lens at 225 mm of total optical extension has an extension ratio of 1.5. Its factor is 1.5² = 2.25, equivalent to log₂(2.25) ≈ 1.17 stops. Starting from a metered 1/125 second at f/16, shutter-only compensation gives 2.25/125 = 0.018 second, or about 1/55.6 second, at f/16. Alternatively, aperture-only compensation gives f/(16 ÷ 1.5), approximately f/10.7, at the original 1/125 second. Keep ISO unchanged for either choice. Under the symmetric-lens assumption, effective f/24 describes the original marked f/16 at this extension; it is not an aperture setting to select. These are mathematical values that may fall between available camera settings.
Magnification relationship
For a simple thin lens, image distance is approximately f × (1 + m). Therefore m ≈ E/f − 1 and the same factor can be written (1 + m)².
Effective aperture
Under the same symmetric-lens assumption, effective f-number is the marked f-number multiplied by E/f. At f/16 and a 1.5× extension ratio, the effective aperture is approximately f/24.
Aperture-only correction
To compensate entirely with aperture, divide the marked f-number by E/f. This changes depth of field and may be impossible when the lens is already near maximum aperture.
Shutter or ISO correction
For increased light exposure, multiply shutter time by F. The ISO-only calculation instead multiplies digital ISO by the same factor: ISO 100 becomes ISO 225 for a 2.25× factor, if that setting is available. At unchanged shutter and aperture, this adjusts brightness without increasing light exposure. For loaded film, changing only the meter’s ISO setting does not compensate for lost light or change film sensitivity; the exposure must change.
Reference: the official Kodak Gray Card guide gives effective f-number as f × (M + 1), exposure factor as (M + 1)², and instructs photographers to multiply exposure time by the factor. Schneider-Kreuznach’s optical imaging formulas describe simplified optical imaging relationships using principal-plane terminology. These references have not been confirmed to support all of the measurement approximations used here, including the rear nodal point terminology, diaphragm or lens-board approximation, and symmetric-lens assumptions.
Measurement accuracy and limits
Field-calculation limit: this is a simple-lens planning model, not a camera or lens calibration. Use manufacturer data, TTL metering, a calibrated meter, or a test exposure when precision matters.
The extension in the formula is an optical image distance, not automatically the outside length of the camera. Measuring to the lens board or diaphragm works reasonably for many conventional lenses because the rear nodal point is nearby, but it can be misleading for telephoto, retrofocus, strongly asymmetric, or internally focusing designs.
The calculator does not model pupil magnification, lens transmission, filters, flash falloff, film processing, or film reciprocity failure. Reciprocity correction is separate and can make a long corrected film exposure longer still. If a through-the-lens meter reads after the lens and extension, it may already observe the light loss; applying a second correction could overexpose the image.
Bellows exposure compensation FAQ
What is the bellows exposure factor?
It is the multiplier applied to metered exposure time to offset light lost as the lens moves farther from the film or sensor. In the simple extension method, factor = (total optical extension ÷ focal length)².
How do I convert the factor to stops?
Take log₂ of the factor. Factor 2 is one stop, factor 4 is two stops, and factor 8 is three stops. A factor of 2.25 is about 1.17 stops.
Is bellows extension the extra draw beyond infinity?
No. Enter the total optical image distance after focusing, not only the added movement beyond the infinity position. At infinity, a simple lens has E/f = 1 and factor 1.
Where should I measure the extension?
Measure from the film or sensor plane to the rear nodal point. The diaphragm or lens-board plane is commonly used as a practical approximation for conventional large-format lenses, but it is not universal.
Does TTL metering already compensate?
Usually a meter reading through the taking lens includes the light actually reaching the camera, but systems differ. Consult the camera instructions and avoid applying the same loss twice.
Why might a telephoto lens give a misleading result?
A telephoto lens can place its rear nodal point well away from the lens board, so physical board-to-film distance is not the optical extension required by the formula.
Is reciprocity failure included?
No. Bellows compensation and reciprocity failure are separate. After calculating the bellows-corrected time, apply the film maker’s reciprocity data when relevant.
Are my settings uploaded?
Whether settings are uploaded or tracked has not been verified. Local-only processing for calculations, copying, and CSV generation is also unconfirmed.